Technical Support: sfb1190-support@gwdg.de
Department of Medical Informatics
University Medical Center Göttingen
SFB 1190 - Imprint
PID | umg-sfb1190-antibody-secondary-0648 |
EPIC PID | https://hdl.handle.net/21.11124/umg-sfb1190-antibody-secondary-0648 |
Research group | AG Lehnart |
Quality (mean) | (5.00) |
Sharing level | Public |
Antibody Registry ID(s) | |
Name | Abberior STAR 635P goat anti-rabbit |
Alternative name | |
Lab ID | |
Tag / Fluorophore | Abberior STAR 635P |
Raised in | Goat |
Clone | |
Isotype | IgG |
Clonality | |
Antigen | rabbit antibodies |
Excitation Max. | 638 nm |
Emission Max. | 651 nm |
Crafted By | company |
Company / Manufacturer | Abberior |
Catalog no. | 2-0012-007-2 |
Lot no. | |
Description | Abberior STAR 635P particularly well suits the Leica TCS STED system and delivers high-resolution STED images with extremely low/no background. The dye serves as an ideal partner for several 2-color STED applications (e.g. in combination with Abberior STAR 488 or Abberior STAR 580). For STED, a depletion wavelength of 750 nm - 780 nm is recommended. |
Localization | |
Storage instruction | 4°C in the dark |
Receipt date | 2017-04-25 00:00:00 |
Preparation date | 2017-04-25 00:00:00 |
Created by | , |
Last modified | , |
Antibodypedia | - |
HGNC | - |
Wikipedia | - |
Uniprot | - |
GeneCards | - |
Antibody Registry | - |
AG | Dilution | Concentration | Quality | Comments | |
---|---|---|---|---|---|
1:1000 | applicable for confocal and STED microscopy |
Glyoxal as an alternative fixative to formaldehyde in immunostaining and super-resolution microscopy.
Richter KN, Revelo NH, Seitz KJ, Helm MS, Sarkar D, Saleeb RS, D'Este E, Eberle J, Wagner E, Vogl C, Lazaro DF, Richter F, Coy-Vergara J, Coceano G, Boyden ES, Duncan RR, Hell SW, Lauterbach MA, Lehnart SE, Moser T, Outeiro T, Rehling P, Schwappach B, Testa I, Zapiec B, Rizzoli SO
EMBO J 2017 : 10.15252/embj.201695709
A protocol for registration and correction of multicolour STED superresolution images
Hebisch E, Wagner E, Westphal V, Sieber JJ, Lehnart SE
J Microsc 2017 : 10.1111/jmi.12556
Direct proteomic and high-resolution microscopy biopsy analysis identifies distinct ventricular fates in severe aortic stenosis
Brandenburg S, Otto L, Schönberger H, Jacob CF, Paulke NJ, Beuthner BE, Topci R, Kohl T, Neuenroth L, Kutschka I, Urlaub H, Kück F, Leha A, Friede T, Seidler T, Jacobshagen C, Toischer K, Puls M, Hasenfuß G, Lenz C, Lehnart SE
J Mol Cell Cardiol 2022 : 10.1016/j.yjmcc.2022.08.363